您的位置: 专家智库 > >

国家自然科学基金(11074168)

作品数:7 被引量:3H指数:1
相关作者:孙洁林李华康亚妮侯婧逸王春梅更多>>
相关机构:上海交通大学中国科学院上海应用物理研究所更多>>
发文基金:国家自然科学基金国家重点基础研究发展计划更多>>
相关领域:生物学自动化与计算机技术医药卫生机械工程更多>>

文献类型

  • 6篇中文期刊文章

领域

  • 3篇生物学
  • 1篇机械工程
  • 1篇自动化与计算...
  • 1篇医药卫生

主题

  • 3篇AFM
  • 2篇FM
  • 2篇FREQUE...
  • 1篇电生理
  • 1篇原子力显微镜
  • 1篇图像
  • 1篇图像配准
  • 1篇图像校正
  • 1篇配准
  • 1篇启动子
  • 1篇转录
  • 1篇转录起始
  • 1篇转录起始位点
  • 1篇位点
  • 1篇温控
  • 1篇裂殖酵母
  • 1篇酵母
  • 1篇核心启动子
  • 1篇PFO
  • 1篇PFTS

机构

  • 3篇上海交通大学
  • 1篇中国科学院上...

作者

  • 3篇孙洁林
  • 1篇胡钧
  • 1篇龙飞
  • 1篇侯婧逸
  • 1篇康亚妮
  • 1篇曲建勋
  • 1篇王春梅
  • 1篇李华

传媒

  • 3篇Journa...
  • 2篇核技术
  • 1篇中国医学物理...

年份

  • 3篇2014
  • 2篇2013
  • 1篇2011
7 条 记 录,以下是 1-6
排序方式:
Direct Resolution of the Pitch of DNA on Positively Charged Lipid Bilayers by Frequency-Modulation AFM
2014年
High resolution structural studies of DNA and DNA binding proteins by atomic force microscopy(AFM) require well-bound samples on suitably flat substrates. Adsorbing the DNA onto a positively charged supported lipid bilayer has previously been shown to be a potentially effective strategy for structural studies with AFM. Here, using our home-built frequency-modulation AFM(FM-AFM), we show that these bilayer substrates are only maximally effective for high resolution AFM when the samples are short, linear DNA, compared with circular plasmid DNA. We find that, with the former sample, the measured width of the DNA is about 2 nm, the known DNA diameter, and there is a clear height modulation along the length of the DNA with a periodicity of about 3.4 nm, in excellent agreement with the known pitch of the double helix. This sample preparation strategy is expected to enable higher resolution studies of DNA and DNA binding proteins with FM-AFM than that can presently be achieved.
张金金吕军鸿孙洁林胡钧CZAJKOWSKY Daniel M沈轶
关键词:DNA
裂殖酵母核心启动子结构的初步研究被引量:2
2013年
位于转录起始位点附近的核心启动子是调控真核生物基因转录的关键区域。近年来发现的高等真核生物核心启动子具有多样的形状、结构和调控机制,使得对核心启动子多样化结构的研究成为了该领域新的研究热点。为研究简单真核生物启动子的结构及其参与调控的机制,我们利用CAGE技术在全基因组范围内捕获裂殖酵母(Schizosaccharomyces pombe)的转录起始位点,从而鉴定其核心启动子序列,并对其形状和序列进行分析。我们的研究揭示了低等真核生物酵母的核心启动子结构具有类似于高等真核生物的多样性,预示着其转录调控可能具有前所未知的复杂性。
侯婧逸李华康亚妮孙洁林
关键词:转录起始位点核心启动子裂殖酵母
基于图像配准的原子力显微镜图像热漂移失真校正被引量:1
2011年
在室温大气环境中,原子力显微镜(AFM)的热漂移会影响扫描过程中针尖定位的精度,导致扫描图像的失真,从而增大基于AFM图像的二维测量的误差。针对这种失真,在图像配准方法的基础上提出了热漂移补偿方法,通过建立热漂移的线性模型,校正扫描的AFM图像,从而恢复样品的真实形貌,有效提高了AFM图像二维平面内的测量准确性。
龙飞王春梅孙洁林胡钧
关键词:原子力显微镜图像校正
Re-evaluation of the Widely Applied Force-Frequency Relation for Frequency-Modulation AFM Under Solution
2014年
Frequency-modulation atomic force microscopy(FM-AFM) is a highly versatile tool for surface science.Besides imaging surfaces, FM-AFM is capable of measuring interactions between the AFM probe and the surface with high sensitivity, which can provide chemical information at sub-nanometer resolution. This is achieved by deconvoluting the frequency shift, which is directly measured in experiments, into the force between the probe and sample. At present, the widely used method to perform this deconvolution has been shown to be accurate under high quality(high-Q) factor vacuum conditions. However, under low quality(low-Q) factor conditions, such as in solution, it is not clear if this method is valid. A previous study apparently verified this relation for experiments in solution by comparing the force calculated by this equation with that obtained in separate experiments using the surface force apparatus(SFA). Here we show that, in solution, a more direct comparison of the force calculated by this relation with that directly measured by the cantilever deflection in AFM reveals significant differences,both qualitative and quantitative. However, we also find that there are complications that hinder this comparison.Namely, while contact with the surface is clear in the direct measurements(including the SFA data), it is less certain in the FM-AFM case. Hence, it is not clear if the two methods are measuring the same tip-sample distance regimes. Thus, our results suggest that a more thorough verification of this relation is required, as application of this formulation for experiments in solution may not be valid.
何健锋胡钧孙洁林CZAJKOWSKY Daniel M
一种平面脂质双分子层电生理平台的循环水浴温控模块搭建方法
2013年
目的:单通道平面脂质双分子层电生理平台是目前研究离子通道特性最直接、最有效的技术手段。为扩展平台研究温度对离子通道电生理特性、通道稳定性等的研究的能力,本文借助循环水浴对平台的温控模块进行设计与实现。方法:本文以Warner公司的脂质双分子层电生理实验平台为操作平台搭建循环水浴温控模块。通过分析温控模块中循环水对平台电流测量的干扰并比较不同循环水排布方式对电流测量的干扰强度,我们设计了折返对偶排布的循环水排布回路,并借助α-溶血素七聚体大孔径离子通道检验该设计的实用效果。该排布方式能够降低循环水回路与电流测量回路间的电磁耦合,进而降低由循环水引入的电磁干扰,保证皮安级小电流的测量。结果:电流噪音可受循环水流回路的排布影响,其中在采用折返对偶排布的情况下,电流噪音与无温控系统空白对照的电流噪音无显著区别。结论:折返对偶排布的循环水流设计能够有效降低循环水温控模块对电流测量的电磁干扰。
曲建勋孙洁林
关键词:温控
Novel Experimental Strategy for High Resolution AFM Imaging of Membrane-Associated Bacterial Toxins
2014年
Bacterial pore-forming toxins(PFTs) are essential virulence factors of many human pathogens. Knowledge of their structure within the membrane is critical for an understanding of their function in pathogenesis and for the development of useful therapy. Atomic force microscopy(AFM) has often been employed to structurally interrogate many membrane proteins, including PFTs, owing to its ability to produce sub-nanometer resolution images of samples under aqueous solution. However, an absolute prerequisite for AFM studies is that the samples are single-layered and closely-packed, which is frequently challenging with PFTs. Here, using the prototypical member of the cholesterol-dependent cytolysin family of PFTs, perfringolysin O(PFO), as a test sample, we have developed a simple, highly robust method that routinely produces clean, closely-packed samples across the entire specimen surface. In this approach, we first use a small Teflon well to prepare the supported lipid bilayer, remove the sample from the well, and then directly apply the proteins to the bilayer. For reasons that are not clear,bilayer preparation in the Teflon well is essential. We anticipate that this simple method will prove widely useful for the preparation of similar samples, and thereby enable AFM imaging of the greatest range of bacterial PFTs to the highest possible resolution.
罗梦麟邵志峰沈轶CZAJKOWSKY Daniel M孙洁林
共1页<1>
聚类工具0