您的位置: 专家智库 > >

国家自然科学基金(11174279)

作品数:7 被引量:9H指数:2
相关作者:宣丽曹召良瞿青张红胜胡立发更多>>
相关机构:中国科学院长春光学精密机械与物理研究所中国科学院大学更多>>
发文基金:国家自然科学基金更多>>
相关领域:理学机械工程自动化与计算机技术电子电信更多>>

文献类型

  • 7篇中文期刊文章

领域

  • 6篇理学
  • 5篇机械工程
  • 1篇电子电信
  • 1篇自动化与计算...
  • 1篇医药卫生

主题

  • 5篇自适应光学
  • 5篇光学
  • 2篇波前
  • 1篇眼底
  • 1篇眼底照相
  • 1篇眼底照相机
  • 1篇液晶波前校正...
  • 1篇英文
  • 1篇三维湍流
  • 1篇视锥细胞
  • 1篇自适应光学系...
  • 1篇望远镜
  • 1篇位相
  • 1篇细胞
  • 1篇相位
  • 1篇相位失真
  • 1篇开环
  • 1篇光学望远镜
  • 1篇光学系统
  • 1篇哈特曼波前传...

机构

  • 2篇中国科学院长...
  • 1篇中国科学院大...

作者

  • 2篇曹召良
  • 2篇宣丽
  • 1篇赵晶丽
  • 1篇穆全全
  • 1篇胡立发
  • 1篇姚丽双
  • 1篇张红胜
  • 1篇徐焕宇
  • 1篇瞿青
  • 1篇张佩光

传媒

  • 3篇Chines...
  • 1篇红外与激光工...
  • 1篇Chines...
  • 1篇Journa...
  • 1篇中国光学

年份

  • 1篇2017
  • 4篇2016
  • 2篇2015
7 条 记 录,以下是 1-7
排序方式:
Multiple-object Shack–Hartmann wavefront sensor design for a wide field of view on the retina被引量:1
2015年
In order to detect the aberration from a wide field of view(FOV) on the retina with adaptive optics, we present a multiple-object Shack–Hartmann wavefront sensor(MOSHWFS) design. The simulated results indicate that the wavefront from our MOSHWFS can be reconstructed for multiple objects, and the measurement error can be less than λ∕7 with an MOSHWFS with an FOV of 6.7°, for maximum eye aberration. The experimental result with two objects indicates that the measurement error can be less than λ∕14, with the root mean square of the reference wavefront as 0.798λ and 0.895λ, respectively.
杨乐宝胡立发李大禹曹召良穆全全马骥宣丽
关键词:哈特曼波前传感器传感器设计自适应光学
A high precision phase reconstruction algorithm for multi-laser guide stars adaptive optics
2016年
Adaptive optics(AO) systems are widespread and considered as an essential part of any large aperture telescope for obtaining a high resolution imaging at present.To enlarge the imaging field of view(FOV),multi-laser guide stars(LGSs) are currently being investigated and used for the large aperture optical telescopes.LGS measurement is necessary and pivotal to obtain the cumulative phase distortion along a target in the multi-LGSs AO system.We propose a high precision phase reconstruction algorithm to estimate the phase for a target with an uncertain turbulence profile based on the interpolation.By comparing with the conventional average method,the proposed method reduces the root mean square(RMS) error from 130 nm to 85 nm with a 30% reduction for narrow FOV.We confirm that such phase reconstruction algorithm is validated for both narrow field AO and wide field AO.
何斌胡立发李大禹徐焕宇张杏云王少鑫王玉坤杨程亮曹召良穆全全鲁兴海宣丽
关键词:自适应光学相位失真
Configuration optimization of laser guide stars and wavefront correctors for multi-conjugation adaptive optics被引量:1
2016年
Multi-conjugation adaptive optics(MCAOs) have been investigated and used in the large aperture optical telescopes for high-resolution imaging with large field of view(FOV).The atmospheric tomographic phase reconstruction and projection of three-dimensional turbulence volume onto wavefront correctors,such as deformable mirrors(DMs) or liquid crystal wavefront correctors(LCWCs),is a very important step in the data processing of an MCAO's controller.In this paper,a method according to the wavefront reconstruction performance of MCAO is presented to evaluate the optimized configuration of multi laser guide stars(LGSs) and the reasonable conjugation heights of LCWCs.Analytical formulations are derived for the different configurations and are used to generate optimized parameters for MCAO.Several examples are given to demonstrate our LGSs configuration optimization method.Compared with traditional methods,our method has minimum wavefront tomographic error,which will be helpful to get higher imaging resolution at large FOV in MCAO.
宣丽何斌胡立发李大禹徐焕宇张杏云王少鑫王玉坤杨程亮曹召良穆全全鲁兴海
关键词:自适应光学光学望远镜三维湍流
Determining the imaging plane of a retinal capillary layer in adaptive optical imaging
2016年
Even in the early stage,endocrine metabolism disease may lead to micro aneurysms in retinal capillaries whose diameters are less than 10 μm.However,the fundus cameras used in clinic diagnosis can only obtain images of vessels larger than 20 μm in diameter.The human retina is a thin and multiple layer tissue,and the layer of capillaries less than10 μm in diameter only exists in the inner nuclear layer.The layer thickness of capillaries less than 10 μm in diameter is about 40 μm and the distance range to rod&cone cell surface is tens of micrometers,which varies from person to person.Therefore,determining reasonable capillary layer(CL) position in different human eyes is very difficult.In this paper,we propose a method to determine the position of retinal CL based on the rod&cone cell layer.The public positions of CL are recognized with 15 subjects from 40 to 59 years old,and the imaging planes of CL are calculated by the effective focal length of the human eye.High resolution retinal capillary imaging results obtained from 17 subjects with a liquid crystal adaptive optics system(LCAOS) validate our method.All of the subjects' CLs have public positions from 127 μm to 147 μm from the rod&cone cell layer,which is influenced by the depth of focus.
杨乐宝胡立发李大禹曹召良穆全全马骥宣丽
关键词:自适应光学系统视锥细胞眼底照相机CLS
位相差值法测量大气湍流格林伍德频率被引量:4
2015年
为了利用位相差值法实现大气湍流格林伍德频率的准确测量,研究了位相差值法的有效性、哈特曼探测器采样点数和采样频率的选取方法。首先给出了位相差值法的基本原理和测量噪声去除方法,然后分析了哈特曼探测器采样点数和格林伍德频率的统计平均次数对测量精度的影响,结果显示,当采样点数大于400、统计平均次数大于400时,可以实现大气湍流格林伍德频率的准确测量。研究了测量噪声的影响,结果表明:去除噪声后,测量值的偏离误差从30%降低到0.6%。研究了算法的重复性精度,得到测量值偏离量的RMS值为1.9 Hz,占理论值的3%,说明测量方法非常稳定。依据上述结果,对8-108 Hz的湍流进行测量和分析,结果显示,当不考虑空气扰动时,测量值与理论值基本一致。最后,研究了哈特曼探测器采样频率和格林伍德频率之间的关系:哈特曼探测器的采样频率越高,能够准确测量的格林伍德频率也越高,并得到了定量的经验公式。上述结果表明,在满足采样点数、采样频率以及统计平均次数等条件下,位相差值法可以实现大气湍流格林伍德频率的准确测量。该研究工作为大气湍流的格林伍德频率测量提供了应用依据。
瞿青曹召良胡立发张红胜赵晶丽宣丽
关键词:大气湍流采样时间
Design of the Rotation Angle Measurement System for the Atmospheric Dispersion Corrector (ADC)
2017年
In order to measure the rotation angle error of the worm and gear mechanisms in the atmospheric dispersion corrector( ADC),a novel measurement system based on the autocollimator is designed in this paper.Based on the position relations between the shaft and spot converged by rays of autocollimator,the rotation angle can be calculated quickly and conveniently using a brief algorithm. An optical wedge is introduced to the measurement system for suppressing the awful measuring error caused by the axial wobbly error. The measurement system can measure the shaft rotation angle at any rotation position,which is the novel usage of the two-dimensional autocollimator. Its optical layout is very simple. Only an optical wedge and two plane mirrors are needed besides the autocollimator. The measurement accuracy of the proposed method is less than±0.5 arcmin. In the measurement of two worms and gears mechanisms in ADC,the rotation angle error are±0.05° and ±0.07° respectively,which all satisfies the design demand( ±0.1°). The proposed measurement system can be also suits for some engineering fields.
Wenjie LiQuanquan MuShaoxin WangChengliang YangHaiping WangZhaoliang CaoLi Xuan
关键词:OPTICALROTATIONAUTOCOLLIMATORAXISOPTICALWEDGE
开环液晶自适应光学系统:研究进展和结果(英文)被引量:3
2016年
对于自适应光学系统,液晶波前校正器是一个非常有前景的波前校正器件。传统的向列相液晶波前校正器的主要缺点是偏振依赖和工作波段窄。采用了基于偏振分束器的开环光路设计和优化的能量分割方法来分别解决上述问题。结果显示,开环光路非常适合于液晶波前校正器,且新颖的能量分割方法显著提高了液晶自适应光学系统的探测能力。
曹召良穆全全徐焕宇张佩光姚丽双宣丽
关键词:开环自适应光学液晶波前校正器
共1页<1>
聚类工具0